Case study · Pond test and filter design

Ob Ob, Nigeria: FoamFlex200 filter cushions for an oily-water drainage system

In the Ob Ob drainage system in Rivers, Nigeria, oily water kept reaching a pond from the skimmer overflow. T1 Solutions tested one FoamFlex200 half carpet (1.5 m long, 340 g) in the pond: it retained 15.28 L of Nigerian Brass Light Crude and 0 L of water over 2 cycles. The result fed a filtration design for the collection basin.
Pond test and filter design
Case type
Drainage system
Site
Light crude
Pollutant
FoamFlex200
Product
.Challenge

What problem did the drainage system have?

Chronic oily-water spills were observed in the Ob Ob drainage system. The overflow from the API skimmer was directed to a pond, so the site needed interception and filtration at strategic points. The solution had to combine containment, filtration and easy recovery of the saturated material, with water levels that change.

The event in numbers
Hydrocarbons retained by one half carpet
0 L
Water picked up
0 L
Reuse cycles in the test
0
Net weight of the half carpet (33 cm x 2.5 cm x 1.5 m)
0 g
Operators handling a FoamFlex carpet at the edge of a pond enclosed by a containment boom, Ob Ob, Nigeria
1
Boom line across the pond
2
Operator handling a FoamFlex carpet
3
Oily water of the pond
Field note · Reading the photo

Boom lines (1) hold the oily water of the pond (3) while an operator handles a FoamFlex carpet (2).

Field note · Reading the photo

Boom lines (1) hold the oily water of the pond (3) while an operator handles a FoamFlex carpet (2).

.Intervention

How was the filter designed?

A pond test gave the numbers, and the filter design followed from them.

1

Test absorption in the pond

One FF200 half carpet was deployed on the oil at 33 C outside temperature, recovered, wrung out and used again for a second cycle.

2

Design the filters

Filtration grids were designed for insertion at the collection basin and conveyance channel. A cage system holds the FoamFlex filter cushions and makes extraction for wringing simple.

3

Compensate the water level

A compensation concept keeps interception stable when the level changes. Retention capacity can be sized from spill assumptions and worst-case scenarios.

.Results

What did the pond test show?

Oil retained, no water

One FF200 half carpet retained 15.28 L of Nigerian Brass Light Crude (API gravity 37.6, viscosity 3.7 mm2/s at 20 C) and 0 L of water, and was reused for 2 cycles.

Retention, not absorption

Below 15 mm2/s viscosity the result is expressed as hydrocarbon retention rather than absorption.

Recommended for operational use

The report suggests a gangway to simplify wringing logistics near the operating area. The official validation recommended operational use.

.Products used

Which products were used?

FoamFlex200 half carpet (FF200 half), 33 cm x 2.5 cm x 1.5 m, net weight 340 g, and filter cushions in cages for the collection basin (design concept).

Reusable

Reusable absorbent carpet with velcro and handles, ideal for all types of spills and compatible with FF-WRING.

Price range: 156,16 € through 268,40 €incl. VAT
.FAQ

Frequently asked questions

15.28 L of Nigerian Brass Light Crude in the Ob Ob pond test, with 0 L of water. The half carpet is 1.5 m long and weighs 340 g.

Place filtration grids at the collection basin or conveyance channel and hold FoamFlex200 filter cushions in cages. The cages let operators pull the cushions out for wringing.

A water-level compensation concept keeps the filter interception stable despite level changes, and retention capacity can be sized from worst-case spill scenarios.

Talk to us about your own spill response